Global solar radiation

Sensors for measuring global irradiation

Radiometers designed for measurement according to ISO 9060 and WMO No. 8 (Part I, Chapter 7). These sensors are classified as an ISO9060 Secondary Standard. With a total daily uncertainty of only 2%, fast response times, these sensors are ideal for users requiring high-level accuracy and reliability.

Global solar radiation

Highlights

  • Spectrally flat Class A pyranometers (Secondary Standard);
  • Compliant with EC 61724-1: 2017;
  • RVH technology: Recirculating Ventilation and Heating (DPA953);
  • Measurement of the angle of inclination (DPA953);
  • Calibration traceable to WRR;
  • Outputs: irradiance in W/m², sensor body temperature, inclination angle, humidity and pressure inside the sensor;
  • Ideal sensor for monitoring the performance of solar panels and meteorological networks.

Global solar radiation

Available Models

radiometro uscita RS485 Modbus

Secondary Standard pyranometers

Pyranometers with a total daily accuracy of only 2%
(ISO9060)
01 radiometro uscita RS485 Modbus

RS485 Modbus output

Secondary standard pyranometer - ventilated and heated
Code: DPA953.1

piranometro uscita analogica

Analogic output

Secondary Standard Pyranometer (ISO9060)
Code: DPA952

piranometro uscita diretta

Direct output

Secondary Standard pyranometer (ISO 9060). Archievable accuracy limited to 2%, fast response time and internal temperature measurement. Direct output from thermopile (uV).
Code: DPA252
piramometro

First Class pyranometers

Pyranometers with 5% total daily accuracy
(ISO9060)
pirometro 01

Direct output

First Class pyranometers (ISO9060). Direct output (uV) from thermopile
Code: DPA154

pirometro 01

0/4-20 mA output integrated

First Class pyranometer (ISO 9060). Integrated electronic for 0/4-20 mA output, power supply 10-30 Vdc
Code: DPA855

pirometro 01

RS485-MODBUS output

First Class pyranometer (ISO 9060). RS485 output and MODBUS-RTU protocol. Internal temperature sensor and input for external temperature sensor for surface temperature measurements.
Code: DPA980
radiometro classe 2

Second Class pyranometers

Pyranometers with 10% total daily accuracy
(ISO9060)
piranometro uscita diretta

Direct output

Second Class pyranometers (ISO9060). Direct output (uV) from thermopile
Code: DPA053A

radiometri uva and uvb

0/4-20 mA output

Second Class pyranometer (ISO 9060) equipped with an external converter for 0/4-20 mA output. Power supply 10-30 Vdc
Code: DPA863

radiometri uva and uvb

Digital output  RS485 MODBUS

Second Class pyranometer (ISO 9060). RS485 output and MODBUS-RTU protocol. Internal temperature sensor and input for external temperature sensor for surface temperature measurements.
Code: DPA983
documents LSI Lastem

Global solar radiation

Documents