MSB – Modbus sensor box
Signal converter (Voltage, Pt100 and Frequency) to RS485 with Modbus RTU protocol
Modbus Sensor Box is a sensor conditioning unit to convert (Volt, Pt100 e Hz) signals into RS485 over RTU Modbus protocol. Modbus sensor box can receive signals from different sensors on the market as: solar irradiance sensor, also pyranometers (configurable sensitivity value), temperature sensors (Pt100) and wind speed sensor (Hz).
Input for Storm distance sensor.
MSB – Modbus sensor box
Signal converter (Voltage, Pt100 and Frequency) to RS485 with Modbus RTU protocol
Modbus Sensor Box is a sensor conditioning unit to convert (Volt, Pt100 e Hz) signals into RS485 over RTU Modbus protocol. Modbus sensor box can receive signals from different sensors on the market as: solar irradiance sensor, also pyranometers (configurable sensitivity value), temperature sensors (Pt100) and wind speed sensor (Hz).
Input for Storm distance sensor.
Signal converter (Voltage, Pt100 and Frequency) to RS485 with Modbus RTU protocol
Modbus Sensor Box is a sensor conditioning unit to convert (Volt, Pt100 e Hz) signals into RS485 over RTU Modbus protocol. Modbus sensor box can receive signals from different sensors on the market as: solar irradiance sensor, also pyranometers (configurable sensitivity value), temperature sensors (Pt100) and wind speed sensor (Hz).
Input for Storm distance sensor.
MSB – Modbus sensor box
Highlights
- N.1 high-resolution input (18 bit) for Pyranometer/reference cell (μV, mV) or 0÷1V. Configurable pyranometer sensitivity value;
- N.2 Pt100 inputs (3-wire) with 0.5°C accuracy;
- N.1 included internal Pt100 temperature sensor as alternative to external sensor;
- N.1 pulse/frequency input for LSI LASTEM wind speed sensors (DNA202-30x);
- N.1 RS232 input for Storm Distance Sensor (DQA601.1);
- Output: instant value and current statistical values (min/avg/max, tot.) for every channel over programmable time base;
- 9÷30 Vdc Power Supply;
- IP66 protection grade.
- N.1 RS232 port on board for configuration using Terminal Emulation program;
- N.1 porta RS485: protocollo Modbus RTU® con protezione galvanica;
- Model code: DSA501.
Documents
This document is not available for download, please contact our Sales Department.
Description
MSB – Modbus sensor box
Highlights
- N.1 high-resolution input (18 bit) for Pyranometer/reference cell (μV, mV) or 0÷1V. Configurable pyranometer sensitivity value;
- N.2 Pt100 inputs (3-wire) with 0.5°C accuracy;
- N.1 included internal Pt100 temperature sensor as alternative to external sensor;
- N.1 pulse/frequency input for LSI LASTEM wind speed sensors (DNA202-30x);
- N.1 RS232 input for Storm Distance Sensor (DQA601.1);
- Output: instant value and current statistical values (min/avg/max, tot.) for every channel over programmable time base;
- 9÷30 Vdc Power Supply;
- IP66 protection grade.
- N.1 RS232 port on board for configuration using Terminal Emulation program;
- N.1 porta RS485: protocollo Modbus RTU® con protezione galvanica;
- Model code: DSA501.
Additional information
Applications | Agro-meteorology, Air quality, Airports and roads, Hydrology, Meteo observations, Museums and archaeological sites, Ports and railways, Renewable energies, Waste cycle |
---|
Reviews
There are no reviews yet.