Air temperature
Sensors for any type of environmental application.
Description
Sensors for any type of environmental application
Pt100 air temperature sensor for indoor use and, coupled with a radiant screen, for meteorological applications. A 4-wire, Pt100 173 DIN B sensing element guarantees very good accuracy over an extended temperature range.
This sensor is ideal for virtually any kind of environmental application.
Air temperature
Highlights
- Accurate temperature measurements (0.1°C);
- 4-wires technology for long distance sensor cable;
- Radiant screen units availability for outdoor measurement under the sun and in meteorological applications;
- Forced ventilation screen availibity;
- Converters for 4-20mA and RS485 Modbus-RTU outputs;
- In house ISO17025 accreditate calibration laboratory;
- Model codes: DMA033.1, DMA033A, EST033.
FAQ: Frequently Asked Questions
Why should an air temperature sensor installed outdoor be installed inside a radiation shield?
Because direct solar radiation and heat emitted by surrounding surfaces can affect the temperature measured by the sensor. A naturally or mechanically ventilated radiation shield protects the sensing element and promotes airflow, making the measurement more representative of the actual air temperature.
What are the advantages of a four-wire Pt100 air temperature sensor?
A four-wire Pt100 sensor compensates for the effect of cable resistance on the measurement. It is therefore especially useful when the sensor is installed far from the data logger or when long cables are used, helping maintain measurement accuracy and stability in extended monitoring systems. LSI LASTEM sensors use 1/3 DIN B Pt100 elements with a four-wire configuration.
In which applications can LSI LASTEM air temperature sensors be used?
Air temperature sensors can be used in meteorological observations, agrometeorology, hydrology, renewable energy, airports, road monitoring, waste management, environmental comfort, conservation in museums and archaeological sites, etc. The choice of radiation shield and configuration should be adapted to the site conditions and measurement objectives.
What does the reliability of air temperature measurement depend on?
Reliability depends on sensor accuracy, proper protection from radiation, correct positioning, ventilation, and calibration quality. LSI LASTEM sensors provide a declared accuracy of 0.1 °C, naturally or mechanically ventilated radiation shields, and the option of calibration certificates issued by the internal ISO/IEC 17025 accredited laboratory.
Additional information
| Applications | Agro-meteorology, Airports and roads, Hydrology, IEQ and environmental comfort, Meteo observations, Museums and archaeological sites, Renewable energies, Waste cycle |
|---|---|
| Grandezze |
Sensors for any type of environmental application
Pt100 air temperature sensor for indoor use and, coupled with a radiant screen, for meteorological applications. A 4-wire, Pt100 173 DIN B sensing element guarantees very good accuracy over an extended temperature range.
This sensor is ideal for virtually any kind of environmental application.
Air temperature
Highlights
- Accurate temperature measurements (0.1°C);
- 4-wires technology for long distance sensor cable;
- Radiant screen units availability for outdoor measurement under the sun and in meteorological applications;
- Forced ventilation screen availibity;
- Converters for 4-20mA and RS485 Modbus-RTU outputs;
- In house ISO17025 accreditate calibration laboratory;
- Model codes: DMA033.1, DMA033A, EST033.
FAQ: Frequently Asked Questions
Why should an air temperature sensor installed outdoor be installed inside a radiation shield?
Because direct solar radiation and heat emitted by surrounding surfaces can affect the temperature measured by the sensor. A naturally or mechanically ventilated radiation shield protects the sensing element and promotes airflow, making the measurement more representative of the actual air temperature.
What are the advantages of a four-wire Pt100 air temperature sensor?
A four-wire Pt100 sensor compensates for the effect of cable resistance on the measurement. It is therefore especially useful when the sensor is installed far from the data logger or when long cables are used, helping maintain measurement accuracy and stability in extended monitoring systems. LSI LASTEM sensors use 1/3 DIN B Pt100 elements with a four-wire configuration.
In which applications can LSI LASTEM air temperature sensors be used?
Air temperature sensors can be used in meteorological observations, agrometeorology, hydrology, renewable energy, airports, road monitoring, waste management, environmental comfort, conservation in museums and archaeological sites, etc. The choice of radiation shield and configuration should be adapted to the site conditions and measurement objectives.
What does the reliability of air temperature measurement depend on?
Reliability depends on sensor accuracy, proper protection from radiation, correct positioning, ventilation, and calibration quality. LSI LASTEM sensors provide a declared accuracy of 0.1 °C, naturally or mechanically ventilated radiation shields, and the option of calibration certificates issued by the internal ISO/IEC 17025 accredited laboratory.